Follow-up of Individual Patients on Two DXA Scanners of the Same Manufacturer

  • Original Article
  • Published:
Osteoporosis International Aims and scope Submit manuscript

Abstract:

Measuring and monitoring changes in bone mineral density (BMD) is usually done by dual-energy X-ray absorptiometry (DXA). Replacement of old devices is becoming increasingly frequent. To cross-calibrate two Hologic devices, a QDR 1000 and a QDR 4500A, we measured three phantoms – a Hologic spine phantom, a Hologic block phantom (without and with subregions analysis) and a European Spine Phantom – 20 times each without repositioning on both devices. The mean difference between BMD obtained on the two devices was 0.003, 0.033, 0.051 and −0.045 g/cm2 respectively. We also measured the spine and hip of 60 women aged 19–78 years twice on the same day on both devices. Another group of 30 women aged 52–83 years were measured twice on the QDR 4500 A device (15 days apart). We analyzed the data using Pearson’s correlation coefficient, and Bland and Altman’s method, and calculated the smallest detectable difference (SDD). Results on the two devices were highly correlated: r 2= 0.99, 0.95, 0.96 for spine, femoral neck and total hip BMD respectively. SDD was higher for scans done on different devices than for those done twice on the same device: the SDDs were 0.048, 0.046 and 0.047 g/cm2 for spine, femoral neck and total hip BMD respectively measured on two different devices, while the equivalent values were 0.034, 0.036 and 0.027 g/cm2 using a single device. The difference in BMD results was not dependent on BMD. Our results suggest that, although devices are properly cross-calibrated, differences among them great enough to be clinically relevant can be observed in vivo.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 30 June 1999 / Accepted: 7 February 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kolta, S., Ravaud, P., Fechtenbaum, J. et al. Follow-up of Individual Patients on Two DXA Scanners of the Same Manufacturer. Osteoporos Int 11, 709–713 (2000). https://doi.org/10.1007/s001980070070

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s001980070070

Navigation