Skip to main content

Main menu

  • Home
  • Content
    • Current issue
    • Past issues
    • Early releases
    • Collections
    • Sections
    • Blog
    • Infographics & illustrations
    • Podcasts
    • COVID-19 Articles
  • Authors & Reviewers
    • Overview for authors
    • Submission guidelines
    • Submit a manuscript
    • Forms
    • Editorial process
    • Editorial policies
    • Peer review process
    • Publication fees
    • Reprint requests
    • Open access
    • Patient engagement
  • Members & Subscribers
    • Benefits for CMA Members
    • CPD Credits for Members
    • Subscribe to CMAJ Print
    • Subscription Prices
  • Alerts
    • Email alerts
    • RSS
  • JAMC
    • À propos
    • Numéro en cours
    • Archives
    • Sections
    • Abonnement
    • Alertes
    • Trousse média 2023
  • CMAJ JOURNALS
    • CMAJ Open
    • CJS
    • JAMC
    • JPN

User menu

Search

  • Advanced search
CMAJ
  • CMAJ JOURNALS
    • CMAJ Open
    • CJS
    • JAMC
    • JPN
CMAJ

Advanced Search

  • Home
  • Content
    • Current issue
    • Past issues
    • Early releases
    • Collections
    • Sections
    • Blog
    • Infographics & illustrations
    • Podcasts
    • COVID-19 Articles
  • Authors & Reviewers
    • Overview for authors
    • Submission guidelines
    • Submit a manuscript
    • Forms
    • Editorial process
    • Editorial policies
    • Peer review process
    • Publication fees
    • Reprint requests
    • Open access
    • Patient engagement
  • Members & Subscribers
    • Benefits for CMA Members
    • CPD Credits for Members
    • Subscribe to CMAJ Print
    • Subscription Prices
  • Alerts
    • Email alerts
    • RSS
  • JAMC
    • À propos
    • Numéro en cours
    • Archives
    • Sections
    • Abonnement
    • Alertes
    • Trousse média 2023
  • Visit CMAJ on Facebook
  • Follow CMAJ on Twitter
  • Follow CMAJ on Pinterest
  • Follow CMAJ on Youtube
  • Follow CMAJ on Instagram
Practice

Cardiac platypnea-orthodeoxia syndrome in a 73-year-old woman

Khai-Jing Ng and Yi-Da Li
CMAJ December 08, 2015 187 (18) 1385-1388; DOI: https://doi.org/10.1503/cmaj.141525
Khai-Jing Ng
School of Medicine (Ng, Li), Tzu Chi University, Hualien, Taiwan; Departments of Internal Medicine (Ng, Li) and Cardiology (Li), Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yi-Da Li
School of Medicine (Ng, Li), Tzu Chi University, Hualien, Taiwan; Departments of Internal Medicine (Ng, Li) and Cardiology (Li), Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: blueway810@yahoo.com.tw
  • Article
  • Figures & Tables
  • Related Content
  • Responses
  • Metrics
  • PDF
Loading

A 73-year-old woman was admitted because of progressive shortness of breath over the previous two weeks, which affected her daily activities. She had a history of congestive heart failure (New York Heart Association functional class II), hypertension and scoliosis. Her medications included acetylsalicylic acid, amiloride, hydrochlorothiazide, atenolol, rosuvastatin and spironolactone. She had no orthopnea or productive cough. On physical examination, her heart sounds were normal, without murmur. An electrocardiogram showed normal sinus rhythm.

During the patient’s stay in hospital, intermittent hypoxemia was noted when she was eating or sitting upright; hypoxemia improved when the patient was lying down. Oxygen saturation was found to step-down gradually, from 90% (when the patient was supine) to 78% (45° recline) to 69% (90° upright), before recovering to 87% (return to supine).

A transthoracic echocardiogram showed a mildly dilated left atrium with a mildly dilated aortic root (3.95 cm). No valvular abnormalities, pericardial effusion or atrial septal aneurysm were seen. Bubbles were seen in the left atrium and ventricle within three cardiac cycles on bubble echocardiography (Figure 1 and Appendix 1, available at www.cmaj.ca/lookup/suppl/doi:10.1503/cmaj.141525/-/DC1), suggesting intracardiac shunting. Computed tomography of the chest showed no evidence of lung parenchymal disease or pulmonary embolism; however, scoliosis and a tortuous, dilated aortic root were noted. Right heart catheterization confirmed normal pulmonary pressure (mean pulmonary arterial pressure 12 mm Hg; mean right atrial pressure 4 mm Hg) and a normal Qp/Qs ratio (0.46). Direct measurement of oxygen saturation during cardiac catheterization showed a step-down pattern: peripheral arterial saturation (SPo2) in pulmonary capillary wedge position, left ventricle and aorta were 99.7%, 85.5% and 88.6%, respectively, which is compatible with the presence of intracardiac right-to-left shunt through a patent foramen ovale. We diagnosed platypnea-orthodeoxia syndrome.

Figure 1:
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1:

Bubble echocardiogram from a 73-year-old woman with progressive shortness of breath. Bubbles (asterisk) were seen in the left atrium (LA) and left ventricle (LV) within three cardiac cycles. We diagnosed platypnea-orthodeoxia syndrome.

The patient was scheduled for transfer to a tertiary care centre for further surgical intervention. Because her oxygen saturation fluctuated between 80%–90% in the supine position, we questioned whether she would be able to tolerate the three-hour journey. Considering the pathophysiology of platypnea-orthodeoxia syndrome, we attempted to increase left ventricular end-diastolic pressure using a vasopressor to improve right-to-left shunting. We initially used low-dose dopamine (5 μg/kg per min). Unfortunately, tachycardia developed, and the patient’s dyspnea and intermittent desaturation did not improve. The patient also felt chest discomfort from palpitations. We changed the vasopressor to norepinephrine (5 μg/hr), which improved the patient’s condition — her oxygen saturation was greater than 95% when she was in a supine position.

The patient was successfully transferred to the tertiary care hospital, where she underwent implantation of a septal occluder. A follow-up cardiac echocardiogram showed no residual shunting, and the patient’s dyspnea decreased substantially after closure of the patent foramen ovale (Appendix 2, available at www.cmaj.ca/lookup/suppl/doi:10.1503/cmaj.141525/-/DC1).

Discussion

Platypnea-orthodeoxia syndrome is an uncommon clinical syndrome that usually presents with a cardinal symptom (platypnea: dyspnea in an upright posture relieved by recumbency) and sign (orthodeoxia: hypoxemia in an upright position).

The exact cause of platypnea-orthodeoxia syndrome is not fully understood, possibly because patients do not present with pulmonary hypertension and right chamber pressure is normal.1,2 Both anatomic and functional abnormalities must be present to cause platypnea-orthodeoxia syndrome.3 The anatomic component refers to the presence of any structural defect which allows interatrial communication, including patent foramen ovale, atrial septal defect and fenestrated atrial septal aneurysm. The functional component refers to any condition that may cause an atrial septum deformity, leading to intracardiac shunting while the patient is in the upright position.3 We speculate that the development of the substantial intracardiac shunt in our patient’s case was likely the result of dilatation of the ascending aorta and kyphoscoliosis, which has been reported to cause abnormal orientation of the heart (Figure 2).4

Figure 2:
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 2:

Computed tomography showing the angle between the interatrial septum (solid line) and the sagittal axis (dotted line). The angle in our patient’s case measured 54.2° (A), whereas 25.4° is considered normal (B). The horizontal orientation of the atrial septum promotes a more direct pathway for venous blood flow, which may directly hit the interatrial septum and cause intracardiac shunting, even without a pressure gradient. LA = left atrium, LV = left ventricle, RA = right atrium.

Patent foramen ovale

Although patent foramen ovale may be clinically silent for decades, patients with this defect may present with cardiac platypnea-orthodeoxia syndrome. It has been proposed that the intracardiac communication caused by a patent foramen ovale results in transiently elevated right chamber pressure, and the “flow” phenomenon (i.e., distortion of anatomy favouring passage of blood to the interatrial communication) may lead to the development of platypnea-orthodeoxia syndrome.2,4,5 In addition, aortic changes (e.g., elongation and dilatation) may cause the atrial septum to become horizontal, thereby promoting a more direct pathway for blood flow from the vena cava to the interatrial communication, despite the absence of a pressure gradient.4,5 Moreover, it has been proposed that an upright position could stretch the interatrial communication, allowing more streaming of venous blood from the inferior vena cava through the defect.3

Investigations

A noninvasive workup including serial oxygen saturation measurements with standard pulse oximetry and echocardiography are usually sufficient to establish the diagnosis of platypnea-orthodeoxia syndrome. Contrast transthoracic echocardiography helps to detect the presence of a right-to-left shunt, whereas transesophageal echocardiography is better for assessing atrial anatomy.6 The gold standard diagnostic test for platypnea-orthodeoxia syndrome remains cardiac catheterization with oxygen measurement directly in the left atrium.6,7

Management

The definitive treatment for cardiac platypnea-orthodeoxia syndrome is percutaneous closure of the interatrial communication, which appears to be safe and efficient, with a low rate of complication.6,8 Other possible diagnoses, such as pulmonary hypertension, should be excluded before closure of the defect to avoid clinical deterioration of the patient’s condition after correction of right-to-left-shunt.

In our patient’s case, we were concerned about the effects of a three-hour journey and reviewed the literature for possible pharmacological interventions to use as a bridge to surgery. However, we found little information. Only one case reported the use of a potent α-adrenergic agonist (metaraminol) to reverse the intracardiac shunt by causing a sharp rise of left ventricular end-diastolic pressure and left atrial pressure in occult atrial septal defect.9

We attempted to increase left ventricular end diastolic pressure using vasopressors, including dopamine and norepinephrine, to temporarily reverse the intracardiac shunting. Norepinephrine is a strong α-receptor agonist and a weak β1-adrenergic agonist, thus producing a dose-dependent systemic vascular resistance and modest increase in cardiac output (Figure 3).

Figure 3:
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 3:

Hemodynamic changes before and after the use of norepinephrine in a patient with platypnea-orthodeoxia syndrome. LA = left atrium, LV = left ventricle, RA = right atrium, RV = right ventricle.

In contrast, dopamine is a dose-dependent vasopressor that has various hemodynamic effects. At low doses (< 3 μg/kg per min), dopamine increases blood flow in renal and splanchnic regions.10 At moderate doses (3–10 μg/kg per min), it stimulates β receptors, increasing myocardial contractility and heart rate while causing peripheral vasodilation.10 At higher doses (> 10 μg/kg per min), dopamine activates α receptors, leading to systemic and pulmonary vasoconstriction.10 However, varying serum drug concentrations can result when dopamine is administered by weight in various patients.11

Norepinephrine successfully reversed the intracardiac shunting in our patient; this effect was probably due to a more selective action of norepinephrine on peripheral vasoconstriction (Figure 3). The moderate dose of dopamine we used likely caused sinus tachycardia or tachyarrhythmia in our patient, which lead to her chest discomfort.

Key points
  • Patients with platypnea-orthodeoxia syndrome may present with shortness of breath, as well as hypoxemia when in an upright position.

  • Careful history-taking and physical examination usually reveal the diagnosis.

  • The treatment of choice for cardiac platypnea-orthodeoxia syndrome is percutaneous closure of the interatrial communication.

  • Vasopressors can be used as a bridge to surgical intervention in patients with platypnea-orthodeoxia syndrome.

See the following videos online: Appendix 1: Bubble echocardiogram. Appendix 2: Follow-up echocardiogram. (Available at www.cmaj.ca/lookup/suppl/doi:10.1503/cmaj.141525/-/DC1.)

The section Cases presents brief case reports that convey clear, practical lessons. Preference is given to common presentations of important rare conditions, and important unusual presentations of common problems. Articles start with a case presentation (500 words maximum), and a discussion of the underlying condition follows (1000 words maximum). Visual elements (e.g., tables of the differential diagnosis, clinical features or diagnostic approach) are encouraged. Consent from patients for publication of their story is a necessity. See information for authors at www.cmaj.ca.

Footnotes

  • Competing interests: None declared.

  • This article has been peer reviewed.

  • The authors have obtained patient consent.

  • Contributors: Both of the authors contributed to the conception, writing and revising of the article. Both of the authors approved the final version to be published and agree to act as guarantors of the work.

References

  1. ↵
    1. Pierce CW
    . Platypnea-orthodeoxia syndrome in an elderly woman with a patent foramen ovale. Can J Cardiol 2010; 26: 213–4.
    OpenUrlCrossRefPubMed
  2. ↵
    1. Rodrigues P,
    2. Palma P,
    3. Sousa-Pereira L
    . Platypnea-orthodeoxia syndrome in review: defining a new disease? Cardiology 2012; 123:15–23.
    OpenUrlCrossRefPubMed
  3. ↵
    1. Cheng TO
    . Mechanisms of platypnea-orthodeoxia: What causes water to flow uphill? Circulation 2002;105:e47.
    OpenUrlFREE Full Text
  4. ↵
    1. Kusunose K,
    2. Yamada H,
    3. Todoroki T,
    4. et al
    . Platypnea-orthodeoxia syndrome associated with patent foramen ovale and aortic ectasia. Echocardiography 2009;26:114–7.
    OpenUrlCrossRefPubMed
  5. ↵
    1. Bertaux G,
    2. Eicher JC,
    3. Petit A,
    4. et al
    . Anotomic interaction between the aortic root and the atrial septum: a prospective echocardiographic study. J Am Soc Echocardiogr 2007;20:409–14.
    OpenUrlCrossRefPubMed
  6. ↵
    1. Blanche C,
    2. Noble S,
    3. Roffi M,
    4. et al
    . Platypnea-orthodeoxia syndrome in the elderly treated by percutaneous patent foramen ovale closure: a case series and literature review. Eur J Intern Med 2013;24:813–7.
    OpenUrlCrossRefPubMed
  7. ↵
    1. Desouza KA,
    2. Saraswat S,
    3. DeSouza SA,
    4. et al
    . Platypnea-orthodeoxia syndrome: a diagnostic challenge. South Med J 2009; 102: 1046–8.
    OpenUrlCrossRefPubMed
  8. ↵
    1. Guérin P,
    2. Lambert V,
    3. Godart F,
    4. et al
    . Transcatheter closure of patent foramen ovale in patients with platypnea-orthodeoxia: results of a multicentric French registry. Cardiovasc Intervent Radiol 2005;28:164–8.
    OpenUrlCrossRefPubMed
  9. ↵
    1. Mackenzie IM,
    2. Banning A,
    3. Dyar O
    . Pharmacologic exposure of an occult atrial septal defect. Crit Care Med 2001;29:1832–4.
    OpenUrlCrossRefPubMed
  10. ↵
    1. Kellum JA,
    2. JMD
    . Use of dopamine in acute renal failure: a meta-analysis. Crit Care Med 2001;29:1526–31.
    OpenUrlCrossRefPubMed
  11. ↵
    1. MacGregor DA,
    2. Smith TE,
    3. Prielipp RC,
    4. et al
    . Pharmacokinetics of dopamine in healthy male subjects. Anesthesiology 2000; 92:338–46.
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Canadian Medical Association Journal: 187 (18)
CMAJ
Vol. 187, Issue 18
8 Dec 2015
  • Table of Contents
  • Index by author

Article tools

Respond to this article
Print
Download PDF
Article Alerts
To sign up for email alerts or to access your current email alerts, enter your email address below:
Email Article

Thank you for your interest in spreading the word on CMAJ.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Cardiac platypnea-orthodeoxia syndrome in a 73-year-old woman
(Your Name) has sent you a message from CMAJ
(Your Name) thought you would like to see the CMAJ web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Cardiac platypnea-orthodeoxia syndrome in a 73-year-old woman
Khai-Jing Ng, Yi-Da Li
CMAJ Dec 2015, 187 (18) 1385-1388; DOI: 10.1503/cmaj.141525

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
‍ Request Permissions
Share
Cardiac platypnea-orthodeoxia syndrome in a 73-year-old woman
Khai-Jing Ng, Yi-Da Li
CMAJ Dec 2015, 187 (18) 1385-1388; DOI: 10.1503/cmaj.141525
Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like

Jump to section

  • Article
    • Discussion
    • Footnotes
    • References
  • Figures & Tables
  • Related Content
  • Responses
  • Metrics
  • PDF

Related Articles

  • Highlights
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • A blistering variant of phlegmasia cerulea dolens from underlying squamous cell lung cancer
  • Parechovirus infections in infants
  • Radiation dermatitis in a patient treated for hepatocarcinoma
Show more Practice

Similar Articles

Collections

  • Article Types
    • Cases
  • Topics
    • Cardiovascular medicine
    • Imaging
    • Respiratory medicine
    • Screening & diagnostic tests

 

View Latest Classified Ads

Content

  • Current issue
  • Past issues
  • Collections
  • Sections
  • Blog
  • Podcasts
  • Alerts
  • RSS
  • Early releases

Information for

  • Advertisers
  • Authors
  • Reviewers
  • CMA Members
  • CPD credits
  • Media
  • Reprint requests
  • Subscribers

About

  • General Information
  • Journal staff
  • Editorial Board
  • Advisory Panels
  • Governance Council
  • Journal Oversight
  • Careers
  • Contact
  • Copyright and Permissions
  • Accessibiity
  • CMA Civility Standards
CMAJ Group

Copyright 2023, CMA Impact Inc. or its licensors. All rights reserved. ISSN 1488-2329 (e) 0820-3946 (p)

All editorial matter in CMAJ represents the opinions of the authors and not necessarily those of the Canadian Medical Association or its subsidiaries.

To receive any of these resources in an accessible format, please contact us at CMAJ Group, 500-1410 Blair Towers Place, Ottawa ON, K1J 9B9; p: 1-888-855-2555; e: cmajgroup@cmaj.ca

Powered by HighWire