[HTML][HTML] Dual-stent retrieval for mechanical thrombectomy of refractory clot in acute stroke as a rescue technique
SN Patro, D Iancu - Cmaj, 2017 - Can Med Assoc
CMAJ| MAY 1, 2017| VOLUME 189| ISSUE 17 E635 limbs, for five minutes. Subsequently,
both stents are gradually retrieved out of the guiding catheter, while continuous suction is …
both stents are gradually retrieved out of the guiding catheter, while continuous suction is …
[HTML][HTML] Mechanical thrombectomy of large vessel occlusion using adjustable vs. self-expanding stent-retriever—Comparison of Tigertriever device with stent-like stent …
P Piasecki, M Wierzbicki, J Narloch, A Dębiec… - Frontiers in …, 2023 - frontiersin.org
Background Stent-retrievers used for mechanical thrombectomy are self-expanding tubular
stent-like devices with modified mesh structures for clot removal. Tigertriever is designed to …
stent-like devices with modified mesh structures for clot removal. Tigertriever is designed to …
Rescue stenting for acute ischemic stroke with refractory emergent large vessel occlusion in the modern thrombectomy era
Background and purpose Rescue stenting is used as a bailout technique during mechanical
thrombectomy for stroke. We performed a retrospective study analyzing outcomes of patients …
thrombectomy for stroke. We performed a retrospective study analyzing outcomes of patients …
ADVANCE: an effective and feasible technique in acute stroke treatment
E Gurkas, CK Akpinar, E Aytac - Interventional …, 2017 - journals.sagepub.com
Background and purpose Different techniques regarding efficient utilization of thrombectomy
devices have been reported. Here, we described a novel technique named ADVANCE that …
devices have been reported. Here, we described a novel technique named ADVANCE that …
[HTML][HTML] Image-based visualization of stents in mechanical thrombectomy for acute ischemic stroke: Preliminary findings from a series of cases
QY Yao, ML Fu, Q Zhao, XM Zheng… - World Journal of …, 2023 - ncbi.nlm.nih.gov
BACKGROUND Mechanical thrombectomy is the most effective treatment for great cerebral
artery embolization within a set time window. Typically, an arteriogram does not show the …
artery embolization within a set time window. Typically, an arteriogram does not show the …
A stent-retrieving into an aspiration catheter with proximal balloon (ASAP) technique: a technique of mechanical thrombectomy
S Goto, T Ohshima, K Ishikawa, T Yamamoto… - World neurosurgery, 2018 - Elsevier
Objective The best technique for the first attempt at mechanical thrombectomy for acute
ischemic stroke is a still matter of debate. In this study, we evaluate the efficacy of a stent …
ischemic stroke is a still matter of debate. In this study, we evaluate the efficacy of a stent …
[HTML][HTML] Endovascular stroke therapy focused on stent retriever thrombectomy and direct clot aspiration: historical review and modern application
DH Kang, J Park - Journal of Korean Neurosurgical Society, 2017 - ncbi.nlm.nih.gov
Intravenous recombinant tissue plasminogen activator had been the only approved
treatment for acute ischemic stroke since its approval in 1995. However, the restrictive time …
treatment for acute ischemic stroke since its approval in 1995. However, the restrictive time …
Comparison of first-pass efficacy among four mechanical thrombectomy techniques: a single-center experience
Background First-pass efficacy (FPE) is an established marker of technical and clinical
efficacy among mechanical thrombectomy (MT) techniques. It is unclear what the optimal …
efficacy among mechanical thrombectomy (MT) techniques. It is unclear what the optimal …
Cost-Effectiveness of a Direct-Aspiration First-Pass Technique versus Stent Retriever in Mechanical Thrombectomy
Objective A direct-aspiration first-pass technique (ADAPT) in mechanical thrombectomy has
been described in recent studies as an efficacious strategy compared with using a stent …
been described in recent studies as an efficacious strategy compared with using a stent …
Hybrid mechanical thrombectomy for acute ischemic stroke using an intermediate aspiration catheter and Trevo stent simultaneously
SH Kim, H Lee, SB Kim, ST Kim, JW Baek… - Journal of Clinical …, 2020 - Elsevier
Purpose To overcome the limitations of traditional mechanical thrombectomy (MT), including
catheter aspiration and stent retrievers, such as thrombus fragmentation or migration, we …
catheter aspiration and stent retrievers, such as thrombus fragmentation or migration, we …
Related searches
- mechanical thrombectomy acute stroke
- mechanical thrombectomy stent retriever
- mechanical thrombectomy series of cases
- mechanical thrombectomy tigertriever device
- mechanical thrombectomy vessel occlusion
- mechanical thrombectomy preliminary findings
- stent retrievers tigertriever device
- vessel occlusions stent retriever
- mechanical thrombectomy cost effectiveness
- matched analysis stent retriever
- cost effectiveness stent retriever
- rescue stenting thrombectomy era
- acute ischemic stroke series of cases
- mechanical thrombectomy visualization of stents
- mechanical thrombectomy stroke centers