Circulation Journal
Online ISSN : 1347-4820
Print ISSN : 1346-9843
ISSN-L : 1346-9843
Rapid Communication
Documented Subacute Stent Thrombosis Within Thirty Days After Stenting With Sirolimus-Eluting Stent (Cypher ®) for Acute Myocardial Infarction
A Japanese Single Center Retrospective Non-Randomized Study
Tetsuya IshikawaMakoto MutohYuji FudaHiroshi SakamotoHisayuki OkadaMichiaki HigashitaniYousuke NakanoJunichi YamaguchiKenji EntaTakahiro SatohKamon ImaiToshinobu HorieSeibu Mochizuki
Author information
JOURNAL FREE ACCESS

2006 Volume 70 Issue 8 Pages 1091-1092

Details
Abstract

Background The incidence of subacute stent thrombosis (SAT) within 30 days after stenting with a sirolimus-eluting stent (Cypher®) for acute myocardial infarction (AMI) was retrospectively compared to that with bare-metal stents (BMS). Methods and Results Among 559 lesions in 558 consecutive AMI from April 2003 to February 2006, the incidence of documented SAT after Cypher® implantation (2/276 lesions, 0.72%) was almost the same as for BMS (2 cases, 0.71%). Aspirin (81-100 mg/day) plus ticlopidine (200 mg/day) were administered continuously after admission in all 4 cases. Conclusion Documented SAT did not increase after stenting with Cypher ® for AMI under aspirin plus ticlopidine. (Circ J 2006; 70: 1091 - 1092)