From the Department of Emergency Medicine, Hamilton Health Sciences (Worster, Opie); the Department of Medicine (Worster, Devereaux, Guyatt), Clinical Epidemiology and Biostatistics (Worster, Devereaux, Heels-Ansdell, Guyatt, Mookadam) and Pathology and Molecular Medicine (Hill), McMaster University; and the Hamilton Regional Laboratory Medicine Program (Hill), Hamilton, Ont.
Correspondence to: Dr. Stephen Hill, Laboratory Medicine, Hamilton General Hospital, 237 Barton St. E, Hamilton, ON L8L 2X2; fax 905 577-8028; hillstev{at}hhsc.ca
| Abstract |
|---|
|
|
|---|
Methods: We screened 546 patients over a 4-week period, of whom 189 fulfilled our entry criteria by presenting to an emergency department with potential cardiac-ischemia symptoms within 6 hours after chest pain, seeing an emergency physician who chose to order a troponin I test, and having no serious cardiac outcome before the troponin result became available. We followed the study patients for 72 hours to determine if any experienced a serious cardiac outcome. We calculated the likelihood ratios (LRs) of IMA findings predicting serious cardiac outcomes that could not be diagnosed at presentation with current techniques.
Results: Of the 189 patients, 24 had a serious cardiac outcome within 72 hours after their arrival at the emergency department. The likelihood ratios for IMA measurement within 6 hours after chest pain predicting a serious cardiac outcome within the next 72 hours were 1.35 (95% confidence interval [CI] 0.3155.79) for IMA
80 U/mL and 0.98 (95% CI 0.86 1.11) for IMA > 80 U/mL.
Conclusions: These data suggest that in patients presenting with chest pain who have not yet experienced a serious cardiac event, IMA is a poor predictor of serious cardiac outcomes in the short term.
Alteration of human serum albumin by ischemia has recently been evaluated as a serum biomarker of cardiac ischemia.1 The amino terminal end (N-terminal) of the albumin molecule is a binding site for transitional metals such as cobalt, copper and nickel.1 Possibly as the result of hypoxia, acidosis, free-radical injury and energy-dependent membrane disruption, the N-terminal undergoes a decrease in binding capacity in the presence of ischemia.2,3,4 This alteration can be measured: a set amount of cobalt is added to the patient's serum, after which a colorimetric assay, the albumin cobalt binding assay, is used to determine the amount of cobalt that remains unbound. An elevated concentration of ischemia-modified albumin (IMA) has, therefore, been proposed as a marker of myocardial ischemic injury.4,5,6 This assay is reported to be positive within minutes of ischemia and remains so for up to several hours later, allowing detection before the development of myocardial necrosis (as evidenced by normal levels of creatinine kinase isoenzyme [CK-MB], troponin and myoglobin).5,7
The ability to detect ischemia before myocyte destruction would allow for earlier and more accurate management decisions for patients suspected of having acute coronary syndrome (ACS) than is currently possible by measuring serum troponin, CK-MB or myoglobin levels. A test that detects all ongoing ischemia that could ultimately cause adverse events would also allow cardiac ischemia to be ruled out, permitting earlier discharge and fewer unnecessary investigations. Because of its potential capacity to identify acute cardiac ischemia, IMA measurement has been proposed as a means to triage patients arriving with symptoms that might result from cardiac ischemia.8 This study sought to determine the capacity of IMA testing to predict serious cardiac outcomes in the short term, in patients presenting to the emergency department with potential cardiac ischemia symptoms.
A study of a diagnostic test is valid insofar as the investigators enrol an appropriate sample of patients and conduct an independent, blinded comparison with the method currently accepted as standard.9 Those in whom the diagnosis is in doubt represent an appropriate sample of patients. Patients presenting with an obvious disease are likely to have a different distribution of test results than those in whom the diagnosis is uncertain. Including such patients will therefore produce a biased and likely, excessively sanguine picture of the usefulness of the test under investigation.
In this case, we were interested in detecting ischemia that leads to death, MI, heart failure, serious arrhythmia or refractory pain during the next 72 hours. Our target population was patients at risk of such adverse events. Patients who arrive in the emergency department having had any of the target events, or who have one before the test result is available, do not need further diagnostic evaluation for their likelihood of subsequently having the event of interest. Furthermore, the distribution of test results from such people is likely to differ from that of patients who remain at risk. Our target sample, therefore, was those patients who remained at risk of adverse events when their first IMA test result was available. Our target finding was the incidence of any of the events of interest, determined by blinded adjudication conducted in duplicate.
| Methods |
|---|
|
|
|---|
Each participant's informed consent, demographic data, symptom characteristics and timing, and cardiac-related medical history were obtained by a research nurse. After a patient consented, blood for IMA measurements was drawn in the emergency department (called time 0) and again 3 and 6 hours later if the patient was not discharged in the meantime. Blood for cTnI levels was also drawn at time 0, and subsequently at the discretion of the emergency physician.
We followed our study patients for 72 hours and recorded their status (alive, dead), location (inpatient, home, returned to hospital), need for therapeutic intervention and whether they had a serious cardiac outcome, defined as any of the following:
Two investigators (J.O. and P.J.D.) independently evaluated all cases of suspected serious cardiac outcomes while blinded to the IMA data. They resolved all disagreements by reaching a consensus opinion.
All blood samples for analysis were collected and transported immediately to the laboratory. Total CK, CK-MB and cTnI assays were done for all patients and the findings made available to clinical staff. Total CK levels were measured with the Roche Modular Analyzer (Roche Diagnostics, Laval, Que.). CK-MB mass and cTnI concentrations were measured with the Abbott AxSym (Abbott Laboratories Canada, Diagnostics Division, Mississauga, Ont.). These assays were done with reagents supplied by the manufacturers and carried out according to their respective protocols. Assay results are expressed as "units" per millilitre (U/mL), as defined by the developers; these are arbitrary units of absorbance derived from the calibration curve.
Red blood cells were immediately separated from serum for IMA analysis and frozen in liquid nitrogen for subsequent analysis. Samples were thawed in small batches; total time at room temperature from blood draw to analysis never exceeded 2 hours. IMA concentration was measured in the Roche Modular assay system by means of reagents, assay protocols and parameters from Ischemia Technologies (Denver, Colo.), in keeping with their recommended sample-handling procedures.
We calculated and have reported the sensitivities, specificities and likelihood ratios (LRs) with 95% confidence intervals (CIs) to describe the association with the occurrence of a serious cardiac outcome of IMA concentrations above or below a single threshold value of 80 U/mL for samples taken at time 0, 3 hours, 6 hours and maximum IMA value. CIs for LRs were computed similarly to relative risk, by first calculating a variance and confidence limits for the logarithm of the LR, then transforming these limits to obtain a CI for the LR. CIs for sensitivity and specificity were calculated with the Wilson score method for binomial proportions. We explored the possibility of multiple thresholds or cut-off values, but the number of events proved too few. We examineded different thresholds, including 85 U/mL as suggested in the manufacturer's package insert, but no threshold produced appreciably different results than our initial choice of 80 U/mL.
The Research Ethics Board of Hamilton Health Sciences and McMaster University approved the protocol.
| Results |
|---|
|
|
|---|
|
|
Differences in demographic and disease characteristics between the 24 patients who experienced a serious cardiac outcome and the 165 who did not were nonsignificant (Table 2). The 24 patients experienced a total of 35 cardiac outcomes (Table 3). Results for IMA analysis fell in a normal distribution from 57 to 138 U/mL (mean 92.3, 95% CI 91.2 93.2, SD 11.5).
|
|
Estimates of diagnostic efficacy demonstrating the association of IMA levels above or below the 80 U/mL threshold value for the 3 times (time 0, 3 and 6 hours) and the maximum value at any time revealed a maximum sensitivity of 92.3% (95% CI 66.7%98.6%), found among patients with an IMA level above 80 U/mL when tested at 6 hours. The maximum specificity by IMA measurement was 24.3% (95% CI 18.2%31.7%), found among patients with serum IMA concentrations of 80 U/mL or less when tested at time 0. In only 1 case did the 95% CIs of the corresponding LRs for each category exceed 10.0 or fall below 0.2 (for 6-hour negative LR, CI 0.1710.03), and all cases included an LR value of 1.0 (Fig. 2).
|
| Interpretation |
|---|
|
|
|---|
In this prospective study IMA results were not made available to physicians responsible for the care of the patient. Rather, we observed the ability of IMA testing to predict serious cardiac outcomes in our usual care model. A test that shows value in a prospective observational trial should then be evaluated in a prospective interventional trial, with test and control groups, to determine if serious cardiac outcomes can be attenuated or avoided with its use.
IMA analysis performed in real time would be available to the physician at about the same time as the troponin result. To examine the usefulness of the test in the situations when it is needed most that is, when other clinical and laboratory tests are not diagnostic we excluded all patients in whom a serious outcome could be diagnosed without the aid of laboratory testing, those admitted before troponin testing, those with diagnostic ECGs and those who suffered serous cardiac outcomes before the troponin result was available.10 Test characteristics are likely to differ in most of these situations because of greater ischemic damage. Thus, inclusion of such patients would give a misleading impression of IMA usefulness in the patients in whom clinicians would need the test to make a decision about hospital admission.
We chose to exclude patients whose chest pains began more than 6 hours before because several references indicate that IMA is rapidly cleared from the circulation after resolution of the period of ischemia and is unlikely to remain elevated longer than 6 hours.5,7
The strengths of this study include the careful selection of the patients for whom clinicians would be using IMA results to make decisions about hospital admission. Our standard for defining target-positive patients was highly patient-relevant: short-term, serious cardiac outcomes including death, MI, congestive heart failure, serious arrhythmia and refractory ischemic cardiac pain. In our evaluation of patients with suspected ACS, we used a 72-hour interval because events during this period dictate the need for immediate admission into the critical care unit.10 We determined occurrence of target events through independent blind adjudication as well as successful follow-up of 188 (of 189) patients.
Since development of the albumincobalt binding assay, investigators have assessed IMA levels in a variety of clinical settings. Although cTnT measurements have been used to indicate that direct-current cardioversion (DCCV) does not cause cardiac damage,11 Roy and colleagues12 reported that in patients with atrial fibrillation, IMA levels are significantly elevated at 1 and 6 hours after DCCV, especially in patients with electrocardiographic evidence of postDCCV ischemia. Sinha and associates13 evaluated ECG, cTnT and IMA levels individually and in combinations in patients diagnosed with non-ischemic chest pain, unstable angina and MI with ST- or nonST-segment elevation. In this population, they found IMA measurements to be the most sensitive of 3 diagnostic tests and declared it to be highly sensitive for the diagnosis of myocardial ischemia in patients presenting with symptoms of ACS.13 Investigators have also reported IMA to be a sensitive measure of the magnitude and duration of ischemia induced during percutaneous coronary intervention (PCI).14,15 A subsequent PCI study supported this finding and also demonstrated a greater increase in IMA level from baseline in patients without collateral coronary-artery circulation than in those with it.16
A recent study17 involving patients with symptoms suggestive of ACS but with normal or nondiagnostic ECGs who came to the emergency department within 3 hours of chest pain documented outcomes at 30 days of ACS (unstable angina or MI with nonST-segment elevation) or non-ischemic chest pain. They measured IMA at presentation and reported positive (LR 2.95, 95% CI 1.914.56) and negative (LR 0.33, 95% CI 0.21 0.52) likelihood ratios using a threshold of 93.5 U/ mL. From this, the investigators concluded that IMA may be a useful marker for the identification of ACS.
As these studies indicate, there is accumulating evidence that IMA levels correlate with, if not quantitatively predict, cardiac ischemic events. However, to the best of our knowledge no studies have been reported that evaluate the diagnostic value of IMA with an exclusive focus on short-term, serious cardiac outcomes in patients for whom IMA might add valuable additional information about need for admission to hospital. Our focus on the relevant population and the most relevant outcome events makes our results directly applicable to the decision faced by physicians seeing patients with potential ACS in the emergency department.
We explored the possibility of multiple IMA thresholds, but the number of events proved too few. We also explored different thresholds (including the 85 U/mL suggested in the manufacturer's package insert), but none produced results that differed appreciably from those of our initial choice, 80 U/mL. Other researchers used cut-off points of 75,7 808 and 85 U/mL.13,17 Given that the 95% CI of the LRs fell outside 0.210 in only 1 instance, and in all cases included a value of 1, our results suggest that IMA levels do not provide information useful in predicting which patients will suffer a serious cardiac outcome in the short term. These results attest to the necessity for thorough evaluation of new diagnostic tests before their dissemination.
ß See related article page 1697
| Footnotes |
|---|
Contributors: Study leader Andrew Worster led the group in protocol development, trial performance and data analysis and interpretation, and wrote the first draft of this report. Stephen Hill, also a principal investigator, led the laboratory component of the trial and was active in assembling and validating the data and preparing the manuscript. As well as taking part in protocol development, P.J. Devereaux organized the adjudication process, took part in data analysis and interpretation, and contributed to manuscript preparation. Statistician Dianne Heels-Ansdell created the database, led the acquisition of data and performed the statistical analysis. Gordon Guyatt not only helped in protocol development, data analysis and interpretation and manuscript preparation, he also provided expert guidance at all stages. John Opie took part in protocol development, helped perform the trial in the emergency department, and adjudicated the clinical data. Farouk Mookadam also helped develop the study protocol, especially during the early stages.
Acknowledgements: P.J. Devereaux is supported by a Senior Research Fellowship Award from the Canadian Institutes of Health Research. We also appreciate the outstanding work of Kim Elliot, who coordinated this study.
This study was supported by a research grant from Ischemia Technologies, Denver, Colo.
Competing interests: None declared for P.J. Devereaux, Dianne Heels-Ansdell, Gordon Guyatt, John Opie and Farouk Mookadam. Andrew Worster and Stephen Hill have received partial coverage of expenses from Ischemia Technologies, Denver, Colo., to attend a meeting at the company office to discuss study plans.
| References |
|---|
|
|
|---|
Related Article
This article has been cited by other articles:
![]() |
A F Manini, J Ilgen, V E Noble, F Bamberg, W Koenig, J S Bohan, and U Hoffmann Derivation and validation of a sensitive IMA cutpoint to predict cardiac events in patients with chest pain Emerg. Med. J., November 1, 2009; 26(11): 791 - 796. [Abstract] [Full Text] [PDF] |
||||
![]() |
P O Collinson and D C Gaze Ischaemia-modified albumin: clinical utility and pitfalls in measurement J. Clin. Pathol., September 1, 2008; 61(9): 1025 - 1028. [Full Text] [PDF] |
||||
![]() |
S. S. Talwalkar, M. Bon-Homme, J. J. Miller, and R. J. Elin Ischemia Modified Albumin, a Marker of Acute Ischemic Events: A Pilot Study Ann. Clin. Lab. Sci., January 1, 2008; 38(2): 132 - 137. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Worster, P.J. Devereaux, and S. Hill Predicting cardiac outcomes Can. Med. Assoc. J., November 8, 2005; 173(10): 1207 - 1207. [Full Text] [PDF] |
||||
![]() |
G. Lippi, M. Montagnana, and G. C. Guidi Predicting cardiac outcomes Can. Med. Assoc. J., November 8, 2005; 173(10): 1206 - 1207. [Full Text] [PDF] |
||||
![]() |
M. S. Sabatine When prognosis precedes diagnosis: putting the cart before the horse Can. Med. Assoc. J., June 21, 2005; 172(13): 1697 - 1698. [Full Text] [PDF] |
||||
Read all eLetters
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||